Battery Charging solutions

15W-6000W

Support non-standard customization development, assist in product certification, and provide upgrade optimization

Product development, replication, program change optimization, certification optimization and other services can be carried out according to customer needs. For etails, please contact

60W lithium battery charger

■ characteristics:

· 100-240Vac universal input voltage

· Automatic detection and full-automatic charging

· constant current and constant voltage mode

· automatic lamp turning after charging

· efficiency up to 80%

100% full load aging test

· refer to ul/ccc/ce/gs standard design

· high life and reliability

· Two year warranty

Detailed information

 

Ternary lithium battery matching table

 

Battery type

Serial number

Battery voltage

Charging voltage

Charging current

Model

 

 

Ternary lithium battery

2

7.4V

8.4V

 5A

HCL-8405000

3

11.1V

12.6V

5A  

HCL-1265000

4

14.8V

16.8V

4A

HCL-1684000

5

18.5V

21V

3A

HCL-213000

6

22.2V

25.2V

2A

HCL-2522000

7

25.9V

29.4V

2A

HCL-2942000

 

 

Iron lithium battery

2

6.4V

7.3V

5A

HCL-7305000

3

9.6V

11V

5A

HCL-1105000

4

12.8V

14.6V

4A  

HCL-1464000

5

16V

18V.25V

3A  

HCL-18253000

6

19.2V

22V

3A

HCL-223000

7

22.4V

25.5V

2.5A

HCL-2552500

8

25.6V

29.2V

2A

HCL-2922000

 

Lead acid battery

1

12V

14.4V

3A

HCL-1443000

2

24V

28.8V

2A

HCL-2882000

3

36V

43.2V

2A

HCL-4322000

4

48V

57.6V

1A

HCL-5761000

technical parameter

input voltage

100-240VAC 50/60Hz

efficiency

80%

Ripple

≦150mv

Input current

≦0.5A

Hold time

 Under full load condition, when the power supply is input at 100vac, the holding time shall not be less than 10ms

Start time

 Under full load condition, when the power supply is input at100vac, the starting time is not more than 3 seconds

Withstand voltage

 Input to output 3000V 60s no breakdown

environment

requirement

temperature

 

Working environment temperature: 0-+40 ℃ storage environment temperature: -20-+75 ℃

humidity

Working time: 20%~85% relative humidity (non condensing) storage time: 10%~90% relative humidity (non condensing)

 

reliability

Mean time between failures

25 ℃ ambient temperature, full load condition, rated voltage input condition, MTBF ≥ 10000 hours (mil-hdbk-217f).

Aging life test

 

The indoor aging life test process of power products will be evaluated and confirmed with the customer

Safety design standard

CE,UL,CCC,GS,FCC